We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
Fabbricante:
(Categoria: 1101)
usato
We are offering for sale a Motor Accessories Package that includes the following machines: Machine 1 Manufacturer: AEG Model: AR630S6B2KB Year: 1990 Enclosure: IP54 Shaft: Ø110 mm, 210 mm length Motor Type: High Voltage Motor Power: 1400.00 Speed: 2989 RPM Voltage: 5000 V Poles: 2 Machine 2 Manufacturer: AEG Model: AR500M6B4KB Year: 1992 Enclosure: IP54 Shaft: Ø100 mm, 210 mm length Motor Type: High Voltage Motor Power: 600.00 Speed: 1492 RPM Voltage: 5000 V Poles: 4 Machine 3 Manufacturer: SCHORCH Model: D3AK 5832/4R Year: 1970 Enclosure: IP33 Shaft: Unknown Motor Type: High Voltage Motor Power: 900.00 Speed: 1490 RPM Voltage: 5000 V Poles: 4 Machine 4 Manufacturer: SIEMENS Model: 1MA1 566-4XZ50-Z Year: 1995 Enclosure: 54 Shaft: Ø140 mm, 250 mm length Motor Type: High Voltage Motor Power: 1400.00 Speed: 1494 RPM Voltage: 5000 V Poles: 4 Ma ...
usato
Manufacturer: MWM Model: TCG 2016 V8 C CHP unit 1 Operating Hours: 22,057 h CHP unit 2 Operating Hours: 9,112 h In addition to the two units themselves, the sale also includes exhaust gas heat exchangers, engine and auxiliary drive control systems, visualization, and a comprehensive spare parts package. Performance Data (Biogas, 50 Hz) - Electrical Output: 400 kWₑ - Voltage / Frequency: 400 V / 50 Hz - Speed: 1500 rpm - Generator: Marelli MJB 355 MB4 - Motor Management System: TEM EVO Efficiency - Electrical Efficiency: 38.0 – 46.4% - Thermal Efficiency: 40.4 – 43.6% - Total Efficiency: Up to 84.4% Engine Configuration - Type: V8 - Bore / Stroke / Displacement: 132 mm / 160 mm / 17.5 liters - Fuel Type: Biogas Heat Recovery (±8%) - Cooling Water Heat: 2080 kW - Mixture Cooler Heat: 5340 kW - Oil Heat: 12000 kW - Exhaust Heat (at cooling): 1136 kW - Radiant Heat (Engine ...
usato
Trasformatori di potenza isolati in olio in vendita Trasformatore 1 - Produttore: ELIN - Modello: TDQ-164A11S9K-99 - Potenza nominale: 15 MVA -Alta tensione: - 121,5 kV (Posizione 0) - 118.463 kV (Posizione -1) - 115.425 kV (Posizione -2) - Bassa tensione: 6,3 kV -Voti: - Alta tensione: 71,3 A (posizione 0), 73,1 A (posizione -1), 75,05 A (posizione -2) - Bassa tensione: 1375 A - Frequenza: 50 Hz - Raffreddamento: ONAN - Anno di costruzione: 1994 - Stato: Fuori servizio dal 2022 - Condizione notevole: Livelli di CO relativamente alti (a causa dell'ossidazione); contenuto insufficiente di inibitore dell'olio. Trattamento dell'olio con inibitore
usato
Trasformatori di potenza isolati in olio in vendita Produttore: ELIN Modello: TDY-164A11S9K-99 Potenza nominale: 15 MVA Alta tensione: - 121,5 kV (Posizione 0) - 118.463 kV (Posizione -1) - 115.425 kV (Posizione -2) Bassa tensione: 6,3 kV Voti: - Alta tensione: 71,3 A (posizione 0), 73,1 A (posizione -1), 75,05 A (posizione -2) - Bassa tensione: 1375 A Frequenza: 50 Hz Raffreddamento: ONAN Anno di costruzione: 1993 Stato: In funzione fino al 2025 Condizione notevole: alti livelli di CO, contenuto insufficiente di inibitori dell'olio. Si consiglia il trattamento dell'olio con reintegro dell'inibitore. Scopri di più qui - / Contattaci
usato
Trasformatori di potenza isolati in olio in vendita - Produttore: ELIN - Modello: JDR 8000/110 - Potenza nominale: 8 MVA -Alta tensione: - 124,85 kV (Posizione 9) - 110 kV (Posizione 0) - 95,15 kV (Posizione -9) - Bassa tensione: 25 kV -Voti: - Alta tensione: 37,5 A (posizione 9), 42,0 A (posizione 0), 47,7 A (posizione -9) - Bassa tensione: 185 A - Frequenza: 50 Hz - Raffreddamento: ONAN - Anno di costruzione: 1960 - Stato: Fuori servizio dall'inizio del 2024 - Condizione notevole: Basso contenuto di inibitori dell'olio e resistenza specifica; In caso contrario, l'olio è in buone condizioni. Trattamento dell'olio con reintegro dell'inibitore
usato
Trasformatori di potenza isolati in olio in vendita Produttore: Brown Boveri Modello: TRFKa 1350/30 Potenza nominale: 1350 kVA Alta tensione: - 26,25 kV (posizione centrale) - 27,56 kV (Posizione 1) - 24,93 kV (Posizione 5) Bassa tensione: 6,3 kV Voti: - Alta tensione: 29,7 A (posizione centrale) - Bassa tensione: 124 A Frequenza: 50 Hz Raffreddamento: ONAN Anno di costruzione: 1972 Stato: In funzione fino a marzo 2025 Condizioni notevoli: alti livelli di CO e contenuto d'acqua; Si consiglia l'essiccazione e il trattamento dell'olio. Scopri di più qui - / Contattaci all'indirizzo -
usato
Produttore: COMUNA-Metall Anno di costruzione: 2008 Tipo di gas: Categoria 12HL Pressione di collegamento: 20-50 mbar Range di potenza nominale: 150/195 kW Tensione: 230/400 V, trifase, 50 Hz Fusibile: NH 00, 100A Pressione di esercizio consentita: 6 bar Potenza termica: 100 kW Potenza elettrica: 50 kW Classe di protezione: IP 54 Temperatura di esercizio consentita: 90/70C Scopri di più qui - / Contattaci all'indirizzo -
usato
Manufacturer: KW Energie Model: Smartblock Year of Manufacture: 2014 Type of Machine: CHP Plant Operating Hours: 17,000 Fuel Type: Natural Gas Engine: Kubota Electrical Output: 22 kW Thermal Output: 50 kW (with condensing boiler use) Fuel Input: 68.4 kW Condition: Fully functional Motor Data - Model: Kubota R24 - Type: Four-Stroke Otto Engine - Cylinder Count: 4 - Displacement: 2.4 Liters - Nominal Speed: 1500 rpm Efficiency Data - Total Efficiency: 105.3% - Electrical Efficiency: 32.2% - Thermal Efficiency: 73.1% - Primary Energy Savings: 34.1% - Primary Energy Factor: 0.36 - Overall Annual Utilization Rate: 105.3% Gas Connection Data - Gas Supply Pressure: 20-50 mbar - Gas Flow Pressure: 16 mbar - Volume Flow (at 0°C, 1013 mbar): 6.8 Nm³/h Temperature Data - Flow Temperature: Max. 85°C - Return Temperature: Max. 65°C - Combustion Air Demand: Min. 75 m³/h - Room ...
usato
Produttore: TEDOM Modello: FLEXI 250 Anno di costruzione: 2022 Tipo di macchina: Centrale di cogenerazione (CHP) Circuito primario - Potenza termica nominale: 369 kW - Pressione massima consentita: 3,5 bar - Temperatura massima consentita: 95C - Categoria: II - Dimensione nominale: 100 - Fluido: Acqua-glicole etilenico - Volume: 350 l Circuito secondario - Potenza termica nominale: 369 kW - Pressione massima consentita: 10 bar - Temperatura massima consentita: 90C - Categoria: Articolo 4, Sezione 3 - Dimensione nominale: 80 - Fluido: Acqua-Glicole Propilenico - Volume: 56 L Pompa di calore reversibile Fabbricante:
usato
Manufacturer: Ansaldo Year of Manufacture: 1999 Technical Data Listing Generator - Type: Three-phase synchronous generator GSCR 800Y4 - Power: 7,250 KVA - Voltage: 10,500V - Frequency: 50 Hz - Phase Number: 3 - Number of Poles: 4 - Rated Current: 398.8A - Power Factor: 0.80 - Rated Speed: 1,500 rpm - Spin Speed: 1,800 rpm - Insulation Heat Resistance Class: F - Ambient Temperature: 40°C - Moment of Inertia of the Rotor: 118.75 kgm² - Winding Connection: Star - Excitation Voltage Rating: 41.2/158.3V - Rated Excitation Current: 54.2/152.3A - Operation Mode: Continuous - Protection Class: IP 4 - Cooling Water Quantity: 660 l/min - Cooling Water Inlet Temperature: 40°C - Cooling Water Inlet Pressure: 4 bar - Air Inlet Temperature: 45°C - Bearing Type: Rolling bearing - Bearing A-side: EMZLB18-200 - Bearing B-side: EMZLQ18-200 - Min. Clearance Shaft/Bearing: 0.267mm - Max. Clearance S ...
usato
Attualmente stiamo offrendo in vendita un impianto di cogenerazione da 50 kW quasi nuovo di Tuxhorn. Indicazioni: - Modello: E50SW (versione a gas naturale) - Anno di fabbricazione : 2022 - Data di messa in servizio: febbraio 2023 - Ore di funzionamento (BH): 45 - Numero di partenze: 59 Caratteristiche speciali: - Dotato di un secondo gas di scarico SD, che riduce il rumore di scarico fino a 35 dB(A) per un funzionamento più silenzioso. Condizione: - Eccellente: l'unità è in condizioni pari al nuovo con un utilizzo minimo. Applicazioni: - Ideale per operazioni industriali o commerciali che richiedono una cogenerazione affidabile ed efficiente. Scopri di più qui -
usato
Termostato, Regolatore di temperatura dell'acqua di raffreddamento, Termostatico MERTIK542.83Temperatura di commutazione: 80° CCollegamenti principali: Ø 50 mmCollegamento secondario: Ø 32 mmMateriale: OttoneNuovo !Dimensioni: 180 x 160 x 100 mm
usato
Convertitore di frequenza, convertitore di frequenzaLOHERFUV 160L2/160L1/6Ingresso: 380 V 28 AUscita: 265 V 48 A 200 HzPotenza: 22 KVAusato, testato ! Immagine simile !Dimensioni: 1030 x 540 x 340 mm
usato
GeneratoreAEMWH 400 L 4690 V910 kW60 Hz1815 giri/mindiametro dell'albero: Ø 110 mmDimensioni: 2200 x 1400 x 1100 mmPeso circa 3..Peso circa 3..br 8 TonNuovo !
usato
Generatore DC per motori per gru DDRVEMGGB 180.BR 1K ( GGB180.1K )TGL 20675 ( TGL20675 )6,2 kW230 V DCmotore: 7,5 kW1435 giri/min380 Vusato, testato ! Dimensioni: 1090 x 360 x 540 mm
usato
GeneratoreEMEDRS 200/10-8anno: 2005115 V52,2 A107 HzDiametro albero: Ø 40 / 45 mmNuovo !' , Dimensioni: 730 x 460 x 470 mm
usato
2007 Mercedes Combined heat and power plant (CHP) The CHP plant was originally intended for an oil platform. Therefore, it is protected against salt water and can also be operated in island mode. Technical data (See pictures) CHP plant with Mercedes engine, which is designed for multi-quality fuel (diesel, heating oil, pyrolysis oil or vegetable oil). Thus preheating unit and corresponding exhaust gas purification. BJ. 2007. Operating hours: 0 (test run only); The unit was never connected to the network. If palm or vegetable oil is used, preheating” is required to get above the pour point. All pumps were completely overhauled by the manufacturer when we purchased them (see Rg with maintenance report). If you want to drive in island mode, this must be changed on the control + the controller on the generator must be replaced. In addition to electricity, the unit can also recover ...
usato
Motore: Jenbacher Works 4T6S Generatore: 725kW Alimentato a diesel Abbiamo installato l'unità in un container da 20 piedi alcuni anni fa. Lo è perfettamente funzionante e funzionante. Scopri di più qui - / Contattaci all'indirizzo -
usato
Generatore di corrente di riserva COME NUOVO! L'attuale numero di ore di funzionamento è di 21 ore. Fabbricante Zeppelin GATTO Modello PPO2000-C32 Anno di costruzione 2007 Peso 26t Dimensioni (L/P/A) 11,0m / 3,0m / 3,2m Condizione Molto buono (usato) Osservazioni/ Info: Motore revisionato nel 2014 400 Volt 50 Hz 1200 KW 2000 kVA 1500 giri/min In base a ciò, i motori CAT sono stati completamente ricondizionati (secondo Zeppelin, il motore è migliore nella riparazione, come un motore nuovo). L'attuale numero di ore di funzionamento è di 21 ore. La macchina è in piedi dal 2014. Eravamo a un
usato
2x Tapping back-pressure turbine with spur gearbox and generator Nr1: Turbine Make: ELIN Type: KR 25 Rated power in relation to the generator terminals: 3800 kW Speed: l0000 rpm Steam inlet pressure max. : 37 Steam inlet temperature max. 44 degrees Tapping pressure max. : 24 Tapping temperature : 390 degrees Evaporation pressure : 2 Normal absorption capacity : 27 t/h Maximum absorption capacity : 32 t/h Gearbox Make Voith, St.Pölten Type D 64 Rated power: 5,700 HP Speed 10 OOO/1 5oo rpm Backpressure steam turbine + gearbox + synchronous generator incl. auxiliaries Nr2: Turbine Make: ELIN Type: KR 25 Rated power in relation to the generator terminals: 43oo kW Speed: 9900 rpm Steam inlet pressure max. 24 atü Steam inlet temperature max. 42o 00 Exhaust steam pressure 2 ata Normal absorption capacity 35 t/h Maximum absorption capacity 35.7 t/h Gearbox Make BHS ...
usato
Power plant (Lambion-Howden-Scheuch-Hamworthy) History - Commissioning: 2009 - Power plant built for the heat supply Manufacturer: Lambion Siemens (turbine, measurement and control technology) Imtech (electrics and performance data: 950 kW rated electrical power 2.00 MW rated thermal output HT(128 128°C) 1.50 MW thermal output NT (85 85°C) 6.74 MW thermal firing capacity Steam output: 7.5 t/h approx. 11,000 tonnes of fuel required per year LPM and WHS Boiler Manufacturer Lambion Year of construction 2008 Maximum steam production [t/h] 7.5 Max. permissible pressure [bar] 32 Max. permissible vapour temperature [ [°C] 440 Turbine / Generator manufacturer Howden Machine TWIN CA 34 Year of construction: 2008 Generator manufacturer: AvK Generator Generator type: DSG 74 M2 System data: Flue gas cleaning Manufacturer Scheuch Condenser / recooling manufa ...
usato
used very little (max 4000 hours) and are in excellent condition. ORC turbine of 160 kW electrical and about 700 kW thermal, The turbine has approximately 7,500 operating hours. Since 2001, Triogen has been developing and manufacturing systems for conversion Organic Rankine Cycle (ORC) energy conversion systems. The generator TRIOGEN ORC, which has been used in various application areas since since 2005, is similar to a steam cycle, but uses a fluid organic instead of water. Compared with steam, it allows to achieve better performance and efficiencies by exploiting sources of low-temperature heat. The Triogen ORC generator is suitable for the conversion of heat from: + Natural gas engines + Biogas engines + Landfill gas engines + Biomass + Biodiesel engines + Diesel engines + Gas from flares + Gas turbines + Process heat + Furnace heat + Any heat source >350 °C 165 ...
usato
3X Identical Steam Turbine sets Each steam turbine set is a complete system except the boiler for the steam generation. If sufficient water vapour is already available from another source, this can also be used. In this case, a boiler is no longer required. The three sets have never been run (like new), however, this sets are already more than 10 years old (year of production 2009). The project for which this sets were purchased has never been implemented. The steam turbine sets are running on 60 Hz. Depending on the country, where the steam turbine sets should be used, they may have to be converted to 50 Hz (replacing the gearbox and the clutch of the generator). This is possible and can be done by experienced companies. We can recommend a German company that has extensive experience in the errection and maintenance of this type of steam turbine. The unused steam turbine sets are pa ...
usato
Model: DOTR 63000/123 Rated Power: 50 / 63 MVA High Voltage (HV): 115 kV High Voltage Tapping Range: +9 / -9 x 1.778% (adjustable under load) Insulation Level HV: 123/550/230 kV Low Voltage (LV): 31.5 kV Insulation Level LV: 36/170/70 kV Tertiary Voltage: 6 kV Insulation Level TW: 12/75/28 kV Frequency: 50 Hz Vector Group: Yynyn0(d) Cooling Method: ONAN / ONAF Maximum Oil Temperature Rise: 60 K Maximum Winding Temperature Rise: 65 K Ambient Temperature Range: -25°C to 40°C Impedance: - At 50 MVA: 15.8% (± IEC-Tolerance) - At 63 MVA: 21% (±7.5%) No-Load Losses: 12.5 kW (+IEC-Tolerance) Load Losses at 50 MVA: 154 kW (+IEC-Tolerance) Noise Power Level at ONAF (No Load): 80 dB(A) Weight Details: - Shipping Weight: Approx. 87,500 kg - Weight of Oil: Approx. 15,300 kg - Active Part: Approx. 58,500 kg - Total Weight: Approx. 89,800 kg Dimensions: - Shipping Dimensions ...
usato
Turbina a vapore 1 e componenti principali Parte dell'impianto Produttore Anno di costruzione techn. dati turbina VEB EKM 1970 generatore VEB EKM; VEB Bergmann Borsig 1970 31250 kVA x 6,3 kV condensatore VEB EKM 1970 inchBearing oil plant, pompe, inchVEB Apparatebau Leisnig-Tragnitz; Raffreddatore con filtro VEM, Siemens, VEB EKM e KSBinch 1969 Pulitore a getto di vapore Wilhelm Wigand 1970 circa Pompe per condensa VEB EKM ca. 1970 Scopri di più qui - / Contattaci all'indirizzo -
usato
Heat and Power Plant with an Absorption Chiller An 850 kW combined heat and power plant with an absorption chiller. The systems ran perfectly until the end and all maintenance was carried out. No damage is known. The CHP ran for 51,429 hours of operation. The absorption chiller has run for 42,350 hours. The following components use an overhauled long block or completely overhauled. The components relevant to assemblies for modernization were marked: - complete panelling - Interfaceschronk - Oil relubrication pump Mechanically overhauled and electrically tested - Oil level monitoring - Plotter heat exchanger - Pressure expansion foll3 (if present) - Pressure transducer and temperature sensors - Rubber rails for motor and generator - Clutch element - Air filter inserts - Safety valves and arnot inserts - Sylomer strips - Hot water preheating pump and heating eleme ...
usato
Tipo di motore BHKW HCI534E2 in vendita Motore a combustione TEDOM tipo DC16 1-013-826. Il blocco motore è stato completamente sostituito solo il 23 maggio Ha ancora diritto all'indennizzo EEG fino al 2031. Scopri di più qui - / Contattaci all'indirizzo -
usato
Steam turbine for sale. The turbine was built in 2012, is in good condition and is no longer in operation. Model SST-060 Turbine with impeller in so-called constant-pressure design (action wheel). The turbine rotor is mounted on two bearings and consists of the above-mentioned impeller and a shaft, which are connected to each other by means of Hirth gearing. The impeller is located outside the bearing and consists of one piece. The blades are milled out of the solid disc. Live steam pressure: 13.0 bara at turbine flange Live steam temperature: 191.6 C at turbine flange Live steam flow max: 10,000 kg/h Exhaust steam pressure: 5.2 bara at turbine exhaust flange Turbo generator sound pressure level: 92 dB(A) z 3 dB(A) measured at a distance of 1 m Coupling power: 275kW Total terminal power: The tolerance is 1.0%. 265kWe The pressure drop for the cyclone to be provided shall be ...